This tab allows configuring watch folders that will monitor transcoding tasks.

To add a new watch folder, press the "+" button. Select one of the following task types from the list that appears:

Select_new_task_type

Currently, four task types are available for configuration in Cinegy Convert Watch Service:

Export from Archive

To automate repetitive export from Cinegy Archive tasks, Cinegy Archive job drop targets are used. Job drop target is a special node type displayed in Cinegy Desktop user interface that allows export tasks submission. To submit a task, add the desired node(s) to the open job drop target container via drag-and-drop. Cinegy Convert Export from Archive watch folders are designed to provide connection between Cinegy Archive job drop targets and Cinegy Convert processing queues.

Export_from_Archive_task_icon

When the "Export from Archive" task is added, it is necessary to configure it using the corresponding form:

Watch_Folder_export_Resource_add
Important
Valid Cinegy Archive connection settings are required to define certain watch folder parameters. Read the CAS Connection article for details.

Connect_button

Press the "Connect" button to establish connection to the specified database.

Disconnect_button

Once the connection is established successfully, it becomes replaced by the "Disconnect" button. Press this button in case you want to abort the connection.

Further parameters are split into two groups:

Export_watch_folder_configuration

The following parameters should be configured in the "Settings" group:

  • File name template – define the file naming template. This field is mandatory. Its default value is {src.name}. Macros can be used in this field.

Note
Please note that unique ID will be automatically appended to the file name to avoid potential clashes with the existing files on the disk.
  • Target folder – define the export job drop target folder in the Cinegy Archive database by pressing the Configure_watch_folder_buttonbutton and selecting the required resource from the dialog that appears.

  • Scheme/target – specify the export scheme by pressing the Configure_watch_folder_buttonbutton and selecting the required resource from the dialog that appears.

  • Quality – select the desired media quality from the drop-down list.

  • Autodegradation – select the checkbox to enable switching to the next available quality.

The "Generic" group allows configuring the following settings:

  • Name – specify the export watch folder name.

  • Description – enter the export watch folder description, if needed.

  • Priority – use the drop-down list to define high, medium or low default task priority.

Having defined all the parameters, press "OK".

Metadata Override

While editing the watch folder configuration, it is possible to override metadata settings from the target scheme selected for it. Press the Profile_Editor_Edit_iconbutton to the right of the "Scheme/target" field and select the "Edit" command:

Scheme_export_edit

The following dialog appears:

Edit_export_scheme_dialog

Here you can change the metadata fields values required for this watch folder.

Import to Archive

Import_to_Archive_task_icon

Having added an "Import to Archive" task, configure it using the corresponding form that appears.

Similarly to the export from archive task type configuration, parameters are split into two groups:

Watch_Folder_import_Resource_add

The "Generic" group allows configuring the following settings:

  • Name – specify the import watch folder name.

  • Description – enter the import watch folder description, if needed.

  • Priority – use the drop-down list to define high, medium or low default task priority.

The following parameters should be configured in the "Settings" group:

  • Scheme/target – specify the import scheme by pressing the Configure_watch_folder_buttonbutton and selecting the required resource from the dialog that appears.

  • Watch folder – define the import folder on the local PC or in a network share by pressing the Configure_watch_folder_buttonbutton; the "Select Folder" dialog appears:

Browse_for_folder_dialog

Select the desired folder or create a new one and press "Select Folder".

Having defined all the parameters, press "OK".

Metadata Override

While editing the watch folder configuration, it is possible to override metadata settings from the target scheme selected for it. Press the Profile_Editor_Edit_iconbutton to the right of the "Scheme/target" field and select the "Edit" command:

Scheme_edit

The following dialog appears:

Edit_scheme_dialog

Here you can change the metadata fields values required for this watch folder. In order to make changes to the database related fields, establish the connection by pressing the "Connect" button.

Edit_scheme_dialog_connected

Transcoding

Transcoding_task_icon

Transcoding task type is used for standalone mode without connection to database required. These tasks perform export/import from one network share to another.

The transcoding task type configuration consists of following parameters that should be set up identically to the other tasks described above.

Watch_Folder_transcoding_Resource_add

The "Generic" group parameters are:

  • Name – specify the transcoding task watch folder name.

  • Description – enter the description, if needed.

  • Priority – use the drop-down list to define high, medium or low default task priority.

The "Settings" group parameters are:

  • Scheme/target – specify the transcoding scheme by pressing the Configure_watch_folder_buttonbutton and selecting the required resource from the dialog that appears.

  • Watch folder – define the folder to be monitored on the local PC or in a network share by pressing the Configure_watch_folder_buttonbutton and selecting the required location from the dialog that appears.

Quality Builder

Quality_builder_task_icon

Quality builder task type is used for automatic creation of non-existent qualities from the highest Cinegy Archive Roll quality available.

The quality builder task type configuration consists of following parameters that should be set up identically to the other tasks described above.

Important
Valid Cinegy Archive connection settings are required to define certain watch folder parameters. Read the CAS Connection article for details.
  • Name – specify the quality builder task watch folder name.

  • Description – enter the description, if needed.

  • Priority – use the drop-down list to define high, medium or low default task priority.

The "Settings" group parameters are:

  • File name template – define the file naming template to be used in Cinegy Archive Quality Builder profiles. This field is mandatory. Its default value is {src.name}. Macros can be used in this field.

    Note
    Please note that unique ID will be automatically appended to the file name to avoid potential clashes with the existing files on the disk.
  • Target folder – specify the Cinegy Archive Quality Builder job drop target by pressing the Configure_watch_folder_buttonbutton and selecting the required resource from the dialog that appears.

  • Quality Builder Schema – select one or several specific TV formats from the drop-down list to use them for quality building.

Having defined the required TV format, you should specify the qualities that will be created in the corresponding Roll:

Quality_builder_parameters

Press the Profile_Editor_Edit_iconbutton and select the required command:

  • Select – select the profile for the corresponding quality creation from the PCS resources list in the dialog that appears.

  • Preserve – use this option to preserve the existing Roll quality, if any.

  • Remove – use this option to remove the existing Roll quality, if any.

Note
The quality building parameters should be specified for each selected TV format separately in the respective settings section.
Note
The "Preserve" option is selected for all qualities by default.