The Cinegy Convert Watch Service requires a valid established connection to the Cinegy Process Coordination Service. By default, the configuration is set to connect to the Cinegy PCS installed locally on the same machine (localhost) and use the default port 8555. In case the Cinegy PCS is installed on another machine or another port should be used, the parameters should be changed correspondingly.

Press the cfg_button button on the bottom right part of the window and choose the "Settings" command. The following window appears:

pcs settings

Here set up the following parameters:

  • Endpoint – by default, the configuration is set to connect to the Cinegy PCS installed locally on the same machine (localhost) and use the default port 8555. In case the Cinegy PCS is installed on another machine or another port should be used, the endpoint value should be modified:

    http://[machine name]:[port]/CinegyProcessCoordinationService/ICinegyProcessCoordinationService/soap

    where:

    • machine name – specifies the name or IP address of the machine where the Cinegy PCS is installed;

    • port – specifies the connection port configured in the Cinegy PCS settings.

  • Heartbeat frequency – time interval for the Cinegy PCS to report it is running properly.

  • Reconnect delay – time interval before the application will re-establish the connection automatically once the connection to the Cinegy PCS is lost.

  • Services update frequency – time interval for the Cinegy PCS to update information about the internal services used by clients.

  • Task creation timeout – time interval defining a timeout for the task to be created. If the task is not created during this interval, the task will fail after the timeout expires. The default value is 120 seconds.

Press "OK" to apply new settings. You will be asked to confirm your choice by the following prevention message:

Watch_service_changes_confirmation

In case changes cannot be applied, the following message will appear, pointing to the reason for negation:

Watch_service_changes_negation